OWNER’S RESOURCES
Everything you need to run and maintain your dry ice blaster — the full user manual, step-by-step video guides, and the status LED and fault-code reference.
Read the status LED panel, then match the pattern against the fault table below.
1
LED 1, standby
2
LED 2, air pressure
3
LED 3, gun
4
LED 4, compressor unit overpressure
5
LED 5, compressor unit motor fault
6
LED 6, dosing unit motor malfunction
Fault
Cause
Rectification
LEDs 1 + 2 light up
Cause
Device ready for use. Power supply switched on, no warning or error messages.
Rectification
No fault.
LED 4 lights up
Cause
Inadequate pressure at the compressed air connection. Pressure sensor detects insufficient pressure for the selected operating mode.
Rectification
LED 3 lights up
Cause
Jet gun fault. The trigger is locked. Trigger is activated/high signal after reset.
Rectification
LED 4, LED 5 and LED 6 flash
Cause
Service mode is activated via the Kärcher Service Interface Protocol (KSIP).
Rectification
LED 3 flashes
Cause
No signal from jet gun available.
Rectification
LED 5 lights up
Cause
Compressor unit electric motor (M70) blocked. No voltage at the compressor unit electric motor (M70).
Rectification
1. Reset motor circuit breaker (Q70).
LED 6 lights up
Cause
Dosing unit electric motor (M80) blocked.
Rectification
1. Reset motor circuit breaker (Q80).
LED 4 flashes
Cause
Compressor pressure switch (W110) has triggered. Pressure in compressor unit too high.
Rectification
LED 6 flashes
Cause
Dosing unit electric motor (M80) not running. Hall sensor reports that the current is too low.
Rectification
1. Switch the device off and on again.