OWNER’S RESOURCES

IB 10/8 L2P

Everything you need to run and maintain your dry ice blaster — the full user manual, step-by-step video guides, and the status LED and fault-code reference.

Kärcher IB 10/8 L2P dry ice blaster

Video Guides

Short walkthroughs for setup, daily operation and routine maintenance.

Troubleshooting

Read the status LED panel, then match the pattern against the fault table below.

Status LED legend

1

LED 1, standby

2

LED 2, air pressure

3

LED 3, gun

4

LED 4, compressor unit overpressure

5

LED 5, compressor unit motor fault

6

LED 6, dosing unit motor malfunction

Fault codes

Fault

Cause

Rectification

LEDs 1 + 2 light up

Cause

Device ready for use. Power supply switched on, no warning or error messages.

Rectification

No fault.

LED 4 lights up

Cause

Inadequate pressure at the compressed air connection. Pressure sensor detects insufficient pressure for the selected operating mode.

Rectification

  1. Increase the pressure at the compressed air connection.
  2. Check the pressure sensor and replace it if necessary.

LED 3 lights up

Cause

Jet gun fault. The trigger is locked. Trigger is activated/high signal after reset.

Rectification

  1. Release the trigger on the jet gun.
  2. Check the button in the trigger, replace if necessary.

LED 4, LED 5 and LED 6 flash

Cause

Service mode is activated via the Kärcher Service Interface Protocol (KSIP).

Rectification

  1. To exit, deactivate the service mode via KSIP or end communication.

LED 3 flashes

Cause

No signal from jet gun available.

Rectification

  1. Check electrical socket plug connection between control line/device.

LED 5 lights up

Cause

Compressor unit electric motor (M70) blocked. No voltage at the compressor unit electric motor (M70).

Rectification

1. Reset motor circuit breaker (Q70).

LED 6 lights up

Cause

Dosing unit electric motor (M80) blocked.

Rectification

1. Reset motor circuit breaker (Q80).

LED 4 flashes

Cause

Compressor pressure switch (W110) has triggered. Pressure in compressor unit too high.

Rectification

  1. Check the exhaust hose.
  2. Check the pressure switch.
  3. CO2 bottle pressure too high, open only half a turn.

LED 6 flashes

Cause

Dosing unit electric motor (M80) not running. Hall sensor reports that the current is too low.

Rectification

1. Switch the device off and on again.